Phone
Email
Address
Building 109, Headquarters Enterprise Base, No. 1 Cuizhu Street, High-tech Zone, Zhengzhou City, Henan Province, China
Diagnosis is missed by an inch, and treatment is a thousand miles away. Laboratory diagnoses can influence more than two-thirds of medical decisions. Innovative solution laboratory solutions for accurate and timely diagnosis are essential for successful treatment.
As a "doctor's doctor", pathology is playing an increasingly central role in the era of precision medicine. Especially in the targeted therapy of tumors, the value of accurate and efficient pathological diagnosis is becoming more and more prominent, and it is the key basis for guiding clinical treatment.
In recent years, with the continuous growth of the number of malignant tumor patients, the workload of the pathology laboratory is increasing day by day. Clinical and patients also put forward higher requirements for the accuracy and timeliness of pathological diagnosis.
Strengthening the intelligent and standardized construction of pathology laboratories is undoubtedly one of the key breakthroughs to improve the quality and efficiency of pathological diagnosis, and promote the high-quality development of precision tumor medicine.
The one-stop solution for complete IHC&ISH workflow. CNT 360 full-automatic IHC&ISH stainer is a powerhouse that performs multiple immunostaining protocols in a single platform, with outstanding fast turnaround time and high-throughput. Ready-to-use reagent kits and protocols are also supplied to ensure optimal staining results.
CNT360-M1 Robot design
M1: 2 main robot arms, 4 bulk liquid trains
Temperature control
The reagent chamber is maintained between 14~ 18Cº
The slide chamber is maintained between 25 ~ 30º for incubation, slides can be heated up to 100º for antigen retrieval
Dispense volume
Dispense volume can be adjusted between 100ul, 120ul, or 150ul for optimal staining results.
Reagent container capacity: 7ml and 30ml
Number of reagent container spots 70 for M1
Bulk liquid container
4L X 6
Waste containers
Non-hazardous, 4L X 3
harzardous, 4L X 1
Slide Capacity
M1: 4 trays, 60 slides
Turnaround Time : 2.5hrs
Touch pads for daily operations, Detachable, remote control allowed
Slide incubation chamber,
15 slides per tray,
4 trays per device,
60 slides per run
Bulk liquid containers, 4L capacity, easily detachable
2 main robot arms for streamlined workflow
Bulk liquid trains on each slide tray,
greatly reduce turnaround time
Motor-driven reagent chamber
70 reagent containers distributed among 5 motor driven reagent trays can separately slide out with one screen-touch.
Instrument Features
Full-automatic
Baking, deparaffinization, antigen retrieval, blocking, detection, counterstain, for IHC, Multiplex IHC and ISH applications.
Intuitive software interface
Visual monitoring of reagent volume, running time, fault message.
Waste Separation
Non-toxic deparaffiniation solution. Separate waste containers for hazardous waste (DAB waste) and non-hazardous waste. Help labs save both time and money spent on waste disposal.
Temperature Control
Constant temperature control for both slide chamber and reagent chamber
Flexibility in slides and reagent placement
Allow loading and unloading of reagent and slides during protocol runs
Allow multiple protocols to run simultaneously
Multifunctional
Support IHC、 ISH、mIHC、ICC protocols
High-throughput
M1: 60 slides per run
Fast turnaround time
2.5 hrs turnaround time, powered by robotic arms and bulk liquid trains,
Intuitive
Detachable touch-pads with remote control capability
Operating temperature
5Cº ~ 35Cº (41F ~ 95F)
2800VA
Voltage and Mains frequency
AC 110V/60Hz or AC 220V/50Hz
Power consumption
2800VA